Second Generator for PSSI Manufacturer,Supplier and Exporter in India
Product Code : EL-EPP-11349
Quick Answer: The Second Generator for the Electrical Power System Simulator is a self-contained motor and generator set, with two coupled machines mounted in the base of its control console. A vector drive controls the motor speed, and manual or automatic excitation controls the generator output.
Last updated: October 2026
Key Features
- Two coupled machines, motor and generator, in the base of the control console
- Vector drive for motor speed; manual or several types of automatic excitation for generator output
- Protection relays, set from the control panels, operate the circuit-breakers around the generator
- Circuit-breakers with hand-operated switches and lamps showing open or closed
- Relay sockets for linking to a computer for more detailed programming
- Multifunction digital meters at the generator output and the utilisation and distribution outputs show all three phases
Technical Specifications
| Specification | Value |
|---|---|
| Machines | Motor and generator set, two coupled machines |
| Speed control | Vector drive |
| Excitation | Manual or automatic |
| Protection | Relays operating circuit-breakers |
| Metering | Digital meters for prime mover and generator; multifunction meters on all three phases |
About This Product
Linked at the higher, transmission voltage, the second generator stands in for central generation such as a main power station. Linked at the lower, utilisation voltage, it represents embedded generation feeding a load directly, for example a generator at a factory or hospital, so students can compare how the two arrangements behave and how generators are protected. Educational Instrument can arrange export supply of the Second Generator for PSSI to Maldives, Mauritius, Latvia, Angola and Nicaragua.
Frequently Asked Questions
How does the second generator connect to the power system?
At the higher voltage (transmission) level to simulate central generation, or at the lower voltage (utilisation) level to simulate embedded generation feeding a load directly.
How is the generator protected?
Relays, set from the control panels, operate the circuit-breakers around the second generator; the breakers also have hand-operated switches and indicator lamps.
Related: Electrical Power Products, Electrical Power Systems, Switched Busbar Module and Modular Power System Hub.
For a quotation on the Second Generator for PSSI, contact Educational Instrument.